From single-line diagram
to witnessed test.

Design, manufacture, testing and support under one roof. It keeps answers short, accountability clear and the finished transformer close to the original intent.

Design engineeringIn-house manufactureRoutine testingFAT & commissioning

One integrated team

Fewer hand-offs. Clearer answers.

The engineer who answers your technical question is part of the same team that builds and tests your transformer. That is how we keep commitments realistic and changes fast.

In-house

Electrical design

Modelled, reviewed and issued by our own engineers.

Unit by unit

Routine testing

No sampling. Every transformer leaves with test records.

By arrangement

Witnessed FAT

Inspect the build and the test results in person.

01 / 06

Design engineering

Every unit begins with an electrical and thermal model built around your duty cycle. We review the design with you before any material is cut.

  • Loss and lifecycle cost evaluation
  • Impedance, fault withstand and insulation coordination
  • Dual-voltage, K-factor and harmonic-rich load designs
  • Thermal modelling for the installed ambient and altitude
  • GA, nameplate and cable-entry drawings
02 / 06

Winding & core manufacture

Windings are built to the design, not to the nearest catalogue size. Conductor, insulation and clamping are controlled through each stage.

  • Copper or aluminium conductor, sized to the duty
  • Step-lap core assembly for low no-load loss and noise
  • Vacuum pressure impregnation for cast resin windings
  • Dimensional and resistance checks before assembly
03 / 06

Tank fabrication & oil processing

Tank and cooling design are matched to the rating, the environment and the transport route. Oil is processed and filled under vacuum.

  • Corrugated-wall, conservator and radiator tanks
  • Leak test and pressure test before filling
  • Vacuum oil filling and oil dielectric verification
  • Sealed-for-life or conservator arrangements
04 / 06

Routine & type testing

Every transformer is routine tested before dispatch. Type and special tests are available to verify behaviour beyond the routine regime.

  • Ratio, vector group, losses and impedance
  • Applied voltage, induced voltage and partial discharge
  • Heat run, impulse and noise measurement on request
  • Documented results issued with the unit
05 / 06

Factory acceptance

Customers are welcome at the works. We agree the inspection and test plan up front and record the results against it.

  • Customer-witnessed FAT
  • Inspection and test plan agreed before manufacture
  • Material and test certificates
  • Export packing and shipping documentation
06 / 06

Delivery & lifecycle support

The relationship does not end at the loading bay. We support installation, commissioning and the long-term condition of the unit.

  • Transport planning and site delivery coordination
  • Installation guidance and commissioning support
  • Spares and replacement accessories
  • Condition assessment and retrofit advice

Testing

We measure before we ship.

Routine tests confirm the electrical and dielectric integrity of every unit. Special tests are available where the duty or the specification calls for deeper verification.

Routine tests

Every unit
  • Ratio, phase displacement and vector group
  • No-load loss and no-load current
  • Load loss and short-circuit impedance
  • Applied voltage (power frequency)
  • Induced voltage
  • Partial discharge measurement
  • Verification of documentation, accessories and clearances

Special & type tests

On request
  • Heat run / temperature-rise test
  • Impulse voltage test
  • Noise level measurement
  • Type tests to project specification

Test scope and acceptance criteria are agreed in the inspection and test plan before manufacture begins.

Documentation

The paperwork matters too.

Every unit is delivered with the drawings and records your maintenance and compliance teams need.

01

General arrangement drawing

Outline dimensions, terminations, lifting points and clearance requirements.

02

Nameplate schedule

Ratings, connection group, impedance, cooling class and mass.

03

Routine test report

Measured values against guaranteed figures, issued before dispatch.

04

O&M manual

Installation, operation, maintenance and safety guidance.

05

Material certificates

Traceability for conductor, core steel and insulation on request.

06

Packing & shipping list

Export packing, lifting plan and delivery documentation.

Looking for a specific test, mounting arrangement or accessory?

Ask the engineering team

Next step

Bring us the difficult one.

Tight rooms, unusual voltages, harmonic loads or a retrofit that has to fit existing cables — those are the projects we are built for.